stannic chloride smoke tubes

  • Allegro Standard Smoke Test Kit - ORR Safety

    Allegro Standard Smoke Test Kit. ... Smoke Tubes (6 per box) ... Stannic Chloride is a white colorless gas with a pungent odor. It fumes strongly in moist air forming ...

  • Page 1/10 Safety Data Sheet (SDS) - nextteq.com

    Page 1/10 Safety Data Sheet (SDS) OSHA HazCom Standard 29 CFR 1910.1200(g), Rev. 2012 and GHS Rev 03. Printing date 10/16/2014 Reviewed on 10/16/2014 39.6.0.1 * 1 Identification · Product identifier · Trade name: Nextteq Irritant Smoke Tube Kit (using Gastec Irritant Smoke Tubes) (P/N 9500) Gastec Irritant Smoke Tubes (P/N 9501) · CAS Number ...

  • HETA 93-0040-2315 NIOSH INVESTIGATORS: MAY 1993 STEVEN W ...

    The fit testing method used by Anchorage involved puffing irritant smoke from air flow indicator tubes into a test hood which encompassed the fire fighter's head and the SCBA's facepiece. The tubes used contain stannic chloride (SnCl4), which reacts with ambient humidity to liberate a white hydrochloric acid fume and tin compounds.

  • Tin(IV) chloride - Wikipedia

    Tin(IV) chloride, also known as tin tetrachloride or stannic chloride, is an inorganic compound with the formula Sn Cl 4. It is a colorless hygroscopic liquid, which fumes on contact with air. It is used as a precursor to other tin compounds. It was first discovered by Andreas Libavius (1550–1616) and was known as spiritus fumans libavii

  • Smoke Tubes from Honeywell/Rae - AFC International

    Smoke generation tubes from Honeywell are designed for use in respirator fit tests or for visualizing air currents. These tubes made of the stannic chloride required by OSHA for irritant smoke fit test procedures. Users include hygienists for chemical plants, confined space entry, fire departments, paint sprayers, and sand blasters.

  • SECTION 1a: IDENTIFICATION SENSIDYNE, LP. th

    Warning. Causes skin irritation and serious eye irritation by contact with smoke. Harmful if inhaled. Stannic chloride reacts with ambient humidity to liberate a white smoke consisting of HCl and tin

  • Stannic Chloride Smoke Tubes | Products & Suppliers ...

    Find Stannic Chloride Smoke Tubes related suppliers, manufacturers, products and specifications on GlobalSpec - a trusted source of Stannic Chloride Smoke Tubes information.

  • STANNIC CHLORIDE, HYDRATED - New Jersey

    * Stannic Chloride, Hydrated is a CORROSIVE CHEMICAL and contact can severely irritate and burn the skin and eyes with possible eye damage. * Breathing Stannic Chloride, Hydrated can irritate the nose and throat causing coughing and wheezing. IDENTIFICATION Stannic Chloride, Hydrated is a white or yellow solid. It is

  • California Code of Regulations, Title 8, Section 5144 ...

    5. Irritant Smoke (Stannic Chloride) Protocol. This qualitative fit test uses a person's response to the irritating chemicals released in the "smoke" produced by a stannic chloride ventilation smoke tube to detect leakage into the respirator.

  • Allegro Standard Smoke Fit Test Kit - safetycompany.com

    Standard Smoke Test kit and replacement items provide a fast, safe and easy method to perform qualitative respirator fit checks on air purifying respirators. When activated, Stannic Chloride is a white colorless gas with a pungent odor. It fumes strongly in moist air forming white hydrochloric acid fume.

  • SPECIFICATIONS - Allegro Industries

    SPECIFICATIONS . Product Description: FIT TEST KIT, STANDARD . Part Number: 2050 . Style: STANNIC CHLORIDE (SMOKE TUBES) GENERAL DESCRIPTION: Provides a fast, safe and easy method to perform qualitative respirator fit checks on air purifying respirators. When activated, Stannic Chloride is a white colorless gas with a pungent odor.

  • Allegro Industries 2055 Deluxe Pump Smoke Test ... - amazon.com

    When activated, Stannic Chloride is a white colorless gas with a pungent odor. It fumes strongly in moist air forming white hydrochloric acid fume. The emitted tin compound has a strong odor that will provoke an involuntary reaction (i.e. coughing) by the test subject.

  • Material Safety Data Sheet Smoke Generating Tubes

    Each tube contains ~0.7 g stannic chloride before use. Stannic chloride and considered corrosive to the skin, eyes and respiratory tract. Contact with moisture releases hydrochloric acid fumes, which is also highly corrosive. Contact with moist air also releases tin compounds, which may be toxic.

  • Nextteq Irritant Smoke Tube Kit - EMLab P&K

    A package of Gastec Irritant Smoke Tubes (part number 9501), which can also be purchased separately, includes the following: part no. Item 1. 9501 One box of Gastec Irritant Smoke Tubes w/ Gastec Instructions and Warnings (Each box contains six tubes with black caps) Not Shown 9505 One Nextteq Irritant Smoke Tube Kit Manual 3 2 1 1

  • 2050 Smoke QLFT Instructions - h2sonlinetraining.com

    • Box of Stannic chloride tubes 6 per box • Smoke Tube Caps 6 EA • Storage pouch 1 EA • Instructions 1 EA 2) Remove contents from box and inspect. 3) Install the piece of ¼" tubing to the hose barb on the air bulb. 4) Take a smoke tube, using the tube breaker twist the tube full circle to score and break off the tube tip.

  • VeriFit - Nextteq LLC

    Fire encompassing the tubes will emit toxic fumes of chlorides. Violently reacts with water to generate heat. Generates smoke with moisture in air. Mixing with alkali metal may result in an explosion. Advice for firefighters If there is a fire around the area where tubes are stored, move the tubes or cool the tubes by dousing with a large amount of

  • Honeywell Training for Fit Testers: Irritant Smoke ...

    Workers need to be properly fitted to their mask to assure that the specific model and size fits and protections the worker from exposure. Learn how to condu...

  • Qualitative Fit Test Form for Stannic Chloride

    16. At each test step introduce smoke to the sealing surface. 17. Give wearer pssing the smoke test, without evidence of response a second sensitivity screening check with the smoke from the same tube. If they react to the smoke, they pass the test. The fit test is void if an employee does not respond to the smoke not wearing the respirator.

  • Smoke Tube Test Kit - BBL Safety

    Smoke generating tubes are designed for use in respirator fit tests. These tubes are of the stannic chloride type required by OSHA for use in the irritant smoke fit test procedure. The tubes can also be used for visualizing air currents, such as in testing the performance of fume hoods or in detecting leaks from an air duct.

  • Qualitative Fit Testing - Quick Tips #324 - Grainger ...

    Irritant Smoke (Stannic Chloride) This qualitative fit test agent uses a person's response to the irritating chemicals released in the "smoke" produced by a stannic chloride smoke tube to detect leakage into the respirator. The stannic chloride reacts with humidity producing a white smoke with a pungent odor.

  • FIT TEST PROTOCOL IRRITANT SMOKE - co.marathon.wi.us

    to the irritating chemicals released in the "smoke" produced by a stannic chloride ventilation smoke tube to detect leakage into the respirator. 1. The respirator to be tested shall be equipped with high efficiency particulate air (HEPA) or P100 series filter(s). 2. Only stannic chloride smoke tubes shall be used for this protocol. 3.

  • STANNIC OXYCHLORIDE IRRITANT SMOKE

    Qualitative Fit Test – Stannic Oxyc hloride Irritant Smoke Test RI DEM ERP 7D-2-8, p. 2 . c. Place the smoke tubes and aspirator bulb near the area entrance, for easy access. 2. Set up 3-4 work tables in the orientation area (the larger area) a. Place the smoke tube and respirator bulb on one table. Tape the test instructions to the top of ...

  • Fit Testing Procedures (Mandatory). - 1910.134 App A ...

    (2) Only stannic chloride smoke tubes shall be used for this protocol. (3) No form of test enclosure or hood for the test subject shall be used. (4) The smoke can be irritating to the eyes, lungs, and nasal passages. The test conductor shall take precautions to minimize the test subject's exposure to irritant smoke.

  • Smoke Generation Tubes (Air Flow Indicator) - Smoke Tubes Kit

    Uniphos Smoke Generation Tubes (Air Flow Indicator) for use with SMT-1 Smoke Tube Kit. Uniphos SMOKE GENERATION TUBES (Air Flow Indicator) can be used for respirator fit testing or to visualize air flows such as in ducting or fume hoods. The tubes are of the stannic chloride type recommended by OSHA for respirator fit testing.

  • Stannic Chloride Smoke Tubes - Image Results

  • 10-123-01 RAE Stannic Chloride Irritant Smoke Tubes pk/6

    RAE Stannic Chloride Irritant Smoke Tubes 10-123-01 RAE Systems Smoke Tubes (Stannic Chloride Irritant) pack of 6 This qualitative fit test agent uses a person's response to the irritating chemicals released in the "smoke" produced by a stannic chloride smoke tube to detect leakage into the respirator.

  • Allegro Industries 2050‐01 Replacement Smoke Tubes, One Size ...

    When activated, Stannic Chloride is a white colorless gas with a pungent odor. It fumes strongly in moist air forming white hydrochloric acid fume. The emitted tin compound has a strong odor that will provoke an involuntary reaction (i.e. coughing) by the test subject.

  • MSDS Smoke tube - gas detector tubes

    A. Tin tetrachloride, Tin (IV) Chloride B. Air Flow Indicator Tube C. Irritant Smoke Generator D. Irritant Smoke Tube Formula : SnCl4 Chemical Family : Metal Chloride Section 2 - Ingredients and Hazards Stannic chloride reacts with ambient humidity to liberate a white smoke consisting of hydrogen chloride (HCl) and tin compounds.

  • MATERIAL SAFETY DATA SHEET SENSIDYNE, INC.

    Material Name: AIR FLOW INDICATOR TUBES Chemical Name & Synonyms: Smoke tubes, Stannic Chloride, CAS No. 7646-78-8, Chemical Family: Metal Chloride Formula: SnCl4 PART II, Ingredients & Hazards % TLV Stannic chloride reacts with ambient humidity to liberate a ca 100 white smoke consisting of HCl and tin compounds. (comb.) 5 ppm ceiling for HCl

  • SAFETY DATA SHEET - allegrosafety.com

    1) Tubes no longer generating smoke require no special treatment DISPOSAL CONSIDERATIONS ECOLOGICAL INFORMATION CAS No 7646-78-8 Stannic chloride, tin tetrachloride Chemical Name Aquatic toxicity 96 48 STABILITY AND REACTIVITY TOXICOLOGICAL INFORMATION Acute fish toxicity LC50 >1000 mg/l Brachydani o rerio Acute crustacean toxicity EC50 21,5 mg/l

  • Smoke Tube Kit, Includes Aspirator Bulb, (2) Rubber Plugs, (6 ...

    Looking for MSA Smoke Tube Kit, Includes Aspirator Bulb, (2) Rubber Plugs, (6) Smoke Tubes, Carrying Case (4LP18)? Grainger's got your back. Price $153.00. Easy online ordering and next-day delivery available with 24/7 expert product support.